advertisement

Topcon

Abstract #100793 Published in IGR 23-1

Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy

Ang RET; Bargas NVR; Martinez GHA; Sosuan GMN; Nabor-Umali MI
Clinical Ophthalmology 2022; 16: 1623-1637


OBJECTIVE: To compare the intraocular pressure (IOP) obtained by Goldmann applanation tonometer (GAT), correcting applanation tonometer surface (CATS) and biomechanically corrected IOP (bIOP) of Corvis ST tonometer (CVS); and to determine the effects of manifest refraction spherical equivalent (MRSE), central corneal thickness (CCT) and mean corneal curvature (Km) on the IOP measurements of corneal refractive patients. METHODS: This was a single-center, retrospective, cross-sectional study of 120 eyes of 64 patients from May 1, 2020 to June 1, 2021 who underwent laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK). The level of agreement between the three tonometers was evaluated, and correlation between parameters was calculated using Pearson correlation. RESULTS: Mean preoperative to postoperative IOP in LASIK and PRK was 15.1 ± 3 to 11.3 ± 2.1 and 14.4 ± 2.6 to 12.1 ± 3 using GAT, 16.4 ± 2.8 to 13.1 ± 2.3 and 15.9 ± 2.6 to 13.7 ± 3 using CATS and 14.8 ± 2.4 to 12.9 ± 1.5 and 14.2 ± 2.4 to 12.6 ± 1.9 using CVS-bIOP. Preoperative IOP correlation between each tonometer pair showed that the lowest mean difference was between GAT and CVS-bIOP (0.32 in LASIK, 0.15 in PRK). Preoperative to postoperative IOP correlation of each tonometer resulted in a difference of 3.77, 2.30 in GAT; 3.32, 2.28 in CATS and 1.88, 1.62 in CVS-bIOP in the LASIK and PRK groups, respectively. Percentage change in CCT and Km was not correlated while change in MRSE had a weak relationship with percentage change in CVS-bIOP. CONCLUSION: Preoperatively, GAT and CVS-bIOP had the best agreement in IOP measurements. CATS recorded the highest IOP preoperatively and postoperatively. IOP decreased in the three tonometers after LASIK and PRK with GAT having the largest decrease. CVS-bIOP had the lowest change between preoperative and postoperative IOP measurements. Only percentage change in MRSE was correlated with percentage change in CVS-bIOP in the LASIK group.

Full article

Classification:

15 Miscellaneous



Issue 23-1

Change Issue


advertisement

Oculus