advertisement

Topcon

Abstract #104642 Published in IGR 23-2

The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

Yang X; Zhao Y; Zhong Y; Duan X
BMC Ophthalmology 2022; 22: 305


BACKGROUND: Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. METHODS: We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. RESULTS: We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. CONCLUSION: Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied.

Changsha Aier Eye Hospital, Changsha, Hunan, China.

Full article

Classification:

15 Miscellaneous



Issue 23-2

Change Issue


advertisement

Oculus