advertisement
PURPOSE: To evaluate visual field changes in primary congenital glaucoma (PCG) with retinal nerve fiber layer thickness on optical coherence tomography. METHODS: In this cross-sectional, observational study, consecutive PCG children who underwent combined trabeculotomy with trabeculectomy and on regular follow-up were enrolled. All patients were aged over four years and co-operative for RNFL OCT and visual field examination. Perimetry was done on Humphrey visual field (HVF) analyzer using 30-2 and 10-2 SITA standard algorithms as appropriate. If a reliable automated perimetry was not feasible, kinetic perimetry was done. The following were noted at baseline and every follow-up: age, sex, visual acuity, intraocular pressure (IOP), cup-disc ratio (CDR), corneal diameters, refraction, any topical antiglaucoma medications, surgeries underwent, age at surgery and duration between surgery and final examination. RESULTS: Forty-eight eyes of 34 children operated for PCG and 19 eyes of 17 controls were analyzed. A statistically significant thinner average RNFL thickness of 87.2 ± 28 μm was noted in PCG eyes as compared to controls with 100.6 ± 7.2 μm (P = 0.04). The mean cup-disc area ratio on OCT in PCG eyes was 0.43 ± 0.2 (0.02-0.93) and in control eyes was 0.23 ± 0.07 (0.1-0.4) (P < 0.001). On RNFL OCT, there was significant focal RNFL loss in temporal superior (P = 0.003), nasal inferior (P = 0.037) and temporal inferior (P < 0.001) quadrants compared to controls. Among PCG eyes, 20/48 eyes (41.7%), had definitive, reproducible glaucomatous VF defects. Mean baseline IOP in PCG eyes with VF defect was 28.7 ± 5.7 mmHg and in eyes with normal VF was 24.6 ± 5.9 mmHg (P = 0.03). On univariate regression analysis, higher baseline IOP was significantly associated with both RNFL loss (odds ratio (OR): -2.17) and VF defects (OR: 3.35). Fluctuation in follow-up IOP (OR: 3.33) was also significantly associated with the presence of VF defects. On multivariable regression analysis maximum, IOP was significantly associated with RNFL loss and VF defects. CONCLUSION: Peripapillary RNFL thickness could be used to identify PCG eyes having visual field loss and possibly poor visual function from PCG eyes without visual field defects. Baseline and follow-up IOP, significantly correlated with RNFL thickness in PCG eyes.
Department of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Full article