Management of XEN Gel Stent Exposure with Conjunctival Erosion via Rotational Conjunctival Flap and Amniotic Membrane Transplantation-A Case Report

Lee CK; Seo JH; Lim SH
Medicina (Kaunas, Lithuania) 2022; 58:


: Despite its proven effectiveness and safety profile, the XEN gel stent (Allergan Inc., CA, USA) for minimally invasive glaucoma surgery (MIGS) has a probability of postoperative complications, including postoperative hypotony, hyphema, stent migration, stent obstruction, bleb fibrosis, and fibrin formation. In particular, the use of adjunctive Mitomycin-C (MMC) might be associated with bleb-related complications, including conjunctival erosion, XEN gel stent exposure, and blebitis. However, there are few studies on XEN gel stent exposure and its management. We describe a case of XEN gel stent exposure with conjunctival erosion 18 months postoperatively, which resolved effectively after combination treatment with a rotational conjunctival flap and amniotic membrane transplantation. : A 74-year-old Korean male patient with diabetes and hypertension underwent uncomplicated ab interno XEN gel stent implantation with a subconjunctival injection of 0.1 cc of 0.02% MMC and presented with low intraocular pressure (IOP) with a well-functioning filtering bleb. Periocular pain and tearing developed 18 months after the initial operation, with mild deterioration of visual acuity to 20/100. Despite conservative medical treatment, the conjunctival erosion was not relieved. Anterior segment optical coherence tomography (AS-OCT) revealed an exposed XEN gel stent with conjunctival erosion. We performed bleb revision surgery using a rotational conjunctival flap and amniotic membrane transplantation. Slit-lamp examination and AS-OCT showed a well-formed moderate bleb without leakage, and IOP continued to be well controlled (14 mm Hg with latanoprost) until six months after bleb revision. : This case report highlights the importance of careful examination, including slit-lamp examination, the Seidel test, and AS-OCT, to identify accurate anatomical positioning and to monitor ocular surface changes after XEN gel stent implantation with MMC or 5-FU. Combination treatment (rotational conjunctival flap and amniotic membrane transplantation) may be relatively safe for persistent XEN gel stent exposure.

Department of Ophthalmology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan 44033, Korea.

Full article

Classification:

15 Miscellaneous



Issue 23-3

Change Issue


advertisement

Oculus