PURPOSE: This study investigates the course of the endothelial cell density over a period of 5 years after XEN45 implantation (XEN45µm, Allergan Plc., USA) with or without combined cataract surgery. METHODS: This is a prospective, cross-sectional, monocentric, non-randomized clinical trial with the intention to treat a population of the University Eye Clinic Glaucoma Service Salzburg. One hundred and fifty-five eyes with preoperative central corneal endothelial cell counts were subjected to XEN45 implantation with (combined surgery group) or without (solo surgery group) combined cataract surgery. Endothelial cell density was measured at 3 corneal positions. XEN45 location parameters were determined with anterior segment OCT and gonioscopy. RESULTS: In the combined surgery group, a significant reduction of central endothelial cell count was found at years 2 and 4 when compared to baseline (p = 0.001 and p = 0.02, n = 86), whereas at years 1, 3, and 5, no change was detected (all p > 0.09). The median reduction of endothelial cell count was - 79 (95% CI: - 183 to - 9) and - 93 (95% CI: - 220 to 23) cells at years 2 and 4, respectively. In the solo surgery group (n = 69), no significant change in endothelial cell counts was detected at any time during the 5-year evaluation period (all p > 0.07). Explorative data analyses revealed that XEN45 location parameters did not significantly influence the course of endothelial cell count over time. CONCLUSIONS: Endothelial cell loss after XEN45 implantation seems to be low. The present data suggest no impact on the position of the implant with regard to central endothelial cell counts in this study.