advertisement

Topcon

Abstract #106927 Published in IGR 23-3

Modified Technique of Ex-PRESS Filtration Device Combined with a Scleral Pocket for Hereditary Transthyretin Amyloidosis (hATTR) Secondary Open-Angle Glaucoma

Vieira R; Vieira R; Marta A; Ferreira A; Figueiredo A; Reis RF; Sampaio I; Sampaio I; Menéres MJ
Clinical Ophthalmology 2023; 17: 403-411


PURPOSE: To evaluate the effectiveness and safety of a modified approach using the Ex-PRESS implant combined with a scleral pocket in the management of secondary open-angle glaucoma in hereditary transthyretin amyloidosis (hATTR) at our department. METHODS: This was a retrospective analysis. The primary endpoints included Intraocular pressure (IOP) evaluation (baseline, 1st day, 1st week, 1, 3, 6, 12 months and at last follow-up) and number of hypotensive drugs (baseline, 6th, 12th months and at last follow-up). As secondary endpoints surgical complications, the need for additional glaucoma surgery and LogMAR BCVA were evaluated. Qualified and complete success were defined as ≥ 30% IOP decrease from baseline, with or without additional medications, respectively. The minimum follow-up was 12 months. RESULTS: A total of 32 eyes were included with a mean follow-up of 2.4±2.9 years. IOP decreased significantly from baseline (27.4±4.4 mmHg) to 1st day (5.00±2.9 mmHg), 1st week (6.9±4.1 mmHg), 1st month (11.7±7.8 mmHg), 3rd month (11.6±6.1 mmHg), 6th month (13.1±6.8 mmHg), 12th month (12.0±3.5 mmHg) and last visit (11.8±2.4 mmHg), p<0.001. There was also a significant reduction in the number of antiglaucoma medications from baseline (3.8±0.6) and last follow-up (0.4±0.8), p<0.001. LogMAR BCVA remained stable (0.25±0.26 at baseline and 0.25±0.24 at last follow-up), p=0.767. Transient hypotony occurred in 17 eyes (53.1%), but only 11 (34.4%) exhibited anterior chamber shallowing and needed additional care, namely cycloplegic drops and viscoelastic injection. Complete surgical success was achieved in 22 eyes (68.8%) and qualified success in 6 eyes (18.8%). Four eyes (12.5%) needed additional glaucoma surgery. CONCLUSION: The modified ExPRESS technique appears to be effective, especially when low levels of IOP are required. Additionally, fewer anti-glaucoma drugs were necessary. In the other hand, hypotony was a common side effect with this procedure, although all patients were properly handled, preserving the surgical outcomes.

Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal.

Full article

Classification:

15 Miscellaneous



Issue 23-3

Change Issue


advertisement

Oculus