advertisement

Topcon

Abstract #112785 Published in IGR 24-3

Retinal Ganglion Cell Functional Recovery after Intraocular Pressure Lowering Treatment Using Prostaglandin Analogs in Glaucoma Suspects: A Prospective Pilot Study

Tirsi A; Gliagias V; Sheha H; Patel B; Moehringer J; Tsai J; Gupta R; Obstbaum SA; Tello C
Journal of Current Glaucoma Practice 2023; 17: 178-190

See also comment(s) by Jonathan Crowston & Jess Tang


AIM AND BACKGROUND: To evaluate the ability of pattern electroretinogram (PERG) to detect improvement of retinal ganglion cell (RGC) function in glaucoma suspects (GS) after medically reducing intraocular pressure (IOP) using prostaglandin analog drops. MATERIALS AND METHODS: Six subjects (eight eyes) received topical IOP lowering treatment based on their clinical examination and were observed at Manhattan Eye, Ear & Throat Hospital over an average of 3.1 ± 2.2 months. During this time, participants underwent a full ophthalmologic exam and were evaluated with a Humphrey visual field analyzer (HFA) 24-2 [24-2 mean deviation (MD), 24-2 pattern standard deviation (PSD), and 24-2 visual field indices (VFI)], Diopsys NOVA PERG optimized for glaucoma [magnitude (Mag), magnitudeD (MagD), and magnitudeD/magnitude ratio (MagD/Mag ratio)] and optical coherence tomography (OCT)-derived average retinal nerve fiber layer thickness (avRNFLT) and average ganglion cell layer + inner plexiform layer (avGCL + IPL) thicknesses at baseline visit (pretreatment) and 3 months later (posttreatment). Goldman applanation tonometry was used to measure IOP at each visit. Paired sample -tests were conducted to determine the statistical significance of the change in IOP, HFA indices, PERG parameters, and OCT thickness measurements between the two visits. RESULTS: Lowering IOP by 22.29% resulted in a significant increase (32.98 and 15.49%) in MagD [ (7) = -3.174, 95% confidence interval (CI) = -0.53, -0.08, = 0.016] and MagD/Mag ratio [ (7) = -3.233, 95% CI = -0.20, -0.03, = 0.014], respectively. There was a positive percentage change for all variables of interest, however, 24-2 MD, Mag, avRNFLT, and GCL+ IPLT did not reach statistical significance. CONCLUSION: After reducing IOP by 22.29% for a duration of 3.1 months, the PERG parameters, MagD and MagD/Mag ratio, significantly improved by 32.98 and 15.49%, respectively. CLINICAL SIGNIFICANCE: Pattern electroretinogram (PERG) may be a crucial tool for clinicians to locate a window of opportunity in which degenerating yet viable RGCs could be rescued from irreversible damage. We suggest consideration of PERG as a tool in early retinal ganglion cell (RGC) dysfunction detection as well as for monitoring IOP lowering treatment. HOW TO CITE THIS ARTICLE: Tirsi A, Gliagias V, Sheha H, Retinal Ganglion Cell Functional Recovery after Intraocular Pressure Lowering Treatment Using Prostaglandin Analogs in Glaucoma Suspects: A Prospective Pilot Study. J Curr Glaucoma Pract 2023;17(4):178-190.

Manhattan Eye, Ear and Throat Hospital; Donald and Barbara Zucker School of Medicine at Hofstra University/Northwell Health, Hempstead, New York, United States.

Full article

Classification:

15 Miscellaneous



Issue 24-1/2

Change Issue


advertisement

WGA Rescources