advertisement

Topcon

Abstract #112812 Published in IGR 24-2

Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma: Two-Year Results from a Randomized, Multicenter Study

Panarelli JF; Moster MR; Garcia-Feijoo J; Flowers BE; Baker ND; Barnebey HS; Grover DS; Khatana AK; Lee B; Nguyen T; Stiles MC; Sadruddin O; Khaw PT;
Ophthalmology 2023; 0:

See also comment(s) by Kin Sheng Lim & Bhavin PatelKaweh Mansouri


PURPOSE: To compare the effectiveness and safety of the MicroShunt (Santen Inc) versus trabeculectomy in patients with primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, multicenter trial conducted in the United States and Europe. PARTICIPANTS: Adult patients (aged 40-85 years) with mild to severe POAG inadequately controlled on maximum tolerated medical therapy and intraocular pressure (IOP) ≥ 15 mmHg and ≤ 40 mmHg. METHODS: Patients were randomized 3:1 to stand-alone MicroShunt implantation (n = 395) or trabeculectomy (n = 132), both augmented with mitomycin C (MMC) 0.2 mg/ml for 2 minutes. MAIN OUTCOME MEASURES: The primary effectiveness end point was surgical success, defined as ≥ 20% reduction in mean diurnal IOP from baseline with no increase in glaucoma medications. Secondary end points included changes in mean IOP and medication use from baseline and the need for postoperative interventions. RESULTS: At 2 years, the rate of surgical success was lower in the MicroShunt group than in the trabeculectomy group (50.6% vs. 64.4%, P = 0.005). Mean diurnal IOP was reduced from 21.1 ± 4.9 mmHg at baseline to 13.9 ± 3.9 mmHg at 24 months in the MicroShunt group and from 21.1 ± 5.0 mmHg at baseline to 10.7 ± 3.7 mmHg at 24 months in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Mean medication use decreased from 3.1 to 0.9 in the MicroShunt group and from 2.9 to 0.4 in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Adverse events at 2 years were generally similar in the 2 groups, except that hypotony was more common in eyes undergoing trabeculectomy (51.1% vs. 30.9%, P < 0.001). Repositioning or explantation of the implant occurred in 6.8% of MicroShunt patients. The majority of these patients had device removal at the time of subsequent glaucoma surgery. Vision-threatening complications were uncommon in both groups. CONCLUSION: At 2 years, both the MicroShunt and trabeculectomy provided significant reductions in IOP and medication use, with trabeculectomy continuing to have greater surgical success. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

New York University, New York, New York.

Full article

Classification:

15 Miscellaneous



Issue 24-1

Change Issue


advertisement

Topcon