Effect of cataract surgery with intraocular lens implant on frequency doubling perimetry

Arvind H; George R; Baskaran M; Raju P; Ramesh SV; Paul PG; Vijaya L
Current Eye Research 2005; 30: 123-128

See also comment(s) by Balwantray Chauhan


PURPOSE: To study the effect of cataract surgery with intraocular lens (IOL) on frequency doubling perimetry (FDP). METHODS: Patients aged 40 years or above seen at our outpatient clinic with no ocular pathology except for visually significant cataract and visual acuity 6/24 or better were eligible. They underwent FDP before and 4 to 6 weeks after cataract surgery with IOL. RESULTS: Screening test: Mean scores by three different scoring methods were 1.82 (3.21), 2.80 (5.54), 4.18 (9.18) before and 0.22 (0.51), 0.26 (0.63), 0.26 (0.69) after surgery (p = 0.002 0.001, < 0.0001). Threshold test: Mean deviation (MD) and pattern standard deviation (PSD) were -5.23 (3.08) and 5.15 (2.78) before and 2.94 (2.49) (p < 0.0001) and 5.21 (1.780) (p = 0.63) after surgery. CONCLUSIONS: The screening test should be interpreted cautiously in the presence of cataract. On threshold testing, cataract surgery causes significant decrease in MD but no change in PSD.

Dr. H. Arvind, Vision Research Foundation, Sankara Nethralaya, Chennai, India


Classification:

6.6.3 Special methods (e.g. color, contrast, SWAP etc.) (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)