The relationship between central corneal thickness-adjusted intraocular pressure and glaucomatous visual-field loss

Sullivan-Mee M; Halverson KD; Saxon GB; Saxon MC; Shafer KM; Sterling JA; Sterling MJ; Qualls C
Optometry 2005; 76: 228-238


BACKGROUND: Although measurement of central corneal thickness (CCT) is increasingly becoming an important component of glaucoma risk analysis, significant controversy exists regarding the benefit of calculating a corrected intraocular pressure (IOP) value from measured IOP and CCT data. METHODS: Three hundred forty-four male subjects were identified from a VA eye clinic with one of the following clinical diagnoses: ocular hypertension (OHT), primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), and normal tension glaucoma suspect (NTGS). Using one eye per subject, multivariate logistic regression and correlational analyses were performed to determine relationships between glaucomatous visual-field loss and several glaucoma risk factors, including adjusted IOP values. RESULTS: Multivariate logistic regression analysis did not identify CCT-adjusted IOP values as independent risk factors for development of either NTG or POAG-related glaucomatous visual-field loss. CCT, however, was found to be strongly associated with both NTG and POAG-related visual-field loss. Correlational analysis revealed a weak correlation between Ehlers-adjusted pre-treatment IOP and severity of POAG-related visual-field loss, but no other adjusted IOP values significantly correlated with severity of visual-field loss in either POAG or NTG. CONCLUSIONS: Our results suggest that adjusted IOP, as calculated using current algorithms, is not useful within glaucoma risk analysis, since adjusted IOP was unable to predict either presence or severity of glaucomatous visual-field loss in this study. CCT, conversely, was found to be a robust and independent predictor of glaucomatous visual-field loss. These findings, while supporting routine CCT measurements for all glaucoma suspects, do not support routine clinical computation of adjusted IOP values using current algorithms.

Dr. Albuquerque VA Medical Center, Eye Clinic, New Mexico 87108, USA. Michael.Sullivan-Mee@med.va.gov


Classification:

2.2 Cornea (Part of: 2 Anatomical structures in glaucoma)
6.1 Intraocular pressure measurement; factors affecting IOP (Part of: 6 Clinical examination methods)



Issue 7-2

Change Issue


advertisement

Topcon