Effect of the AcrySof Natural intraocular lens on blue-yellow perimetry

Kara-Junior N; Jardim JL; de Oliveira Leme E; Dall'Col M; Junior RS
Journal of Cataract and Refractive Surgery 2006; 32: 1328-1330


PURPOSE: To assess the differences in blue-yellow perimetry values in patients with an AcrySof Natural intraocular lens (IOL) in 1 eye and a conventional AcrySof IOL in the fellow eye. SETTING: Cataract and glaucoma clinics of a medical school associated with a public hospital in Brazil. METHODS: Forty-six patients had bilateral phacoemulsification and implantation of an AcrySof SN60AT IOL (Alcon) in 1 eye and an MA30AC IOL (Alcon) in the fellow eye. Blue-yellow perimetry was performed in both eyes, and the data were analyzed in blinded fashion using the Mann-Whitney U test. RESULTS: No statistically significant differences were observed in short-wavelength automated perimetry (SWAP) values between the 2 IOLs. CONCLUSION: There was no interference by the yellow filter of the AcrySof Natural IOL in blue-yellow perception as determined by SWAP.

Dr. N. Kara-Junior, Hospital das Clinicas de Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil


Classification:

6.6.3 Special methods (e.g. color, contrast, SWAP etc.) (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)