Filtering bleb evaluation with slit-lamp-adapted 1310-nm optical coherence tomography

Muller M; Hoerauf H; Geerling G; Pape S; Winter C; Huttmann G; Birngruber R; Laqua H
Current Eye Research 2006; 31: 909-915

See also comment(s) by Paul Palmberg


PURPOSE: Investigation of slit-lamp-adapted 1310-nm optical coherence tomography (OCT) as an in vivo imaging device in the postoperative course of glaucoma surgery. METHODS: Postoperative images of filtering blebs and deep sclerectomies and their healing processes were qualitatively evaluated with a slit-lamp-adapted anterior segment OCT (AS-OCT; Heidelberg Engineering, Heidelberg, Germany) in 28 patients. Ophthalmologic examinations included slit-lamp examination, applanation tonometry, and slit-lamp photography. The OCT scans were qualitatively correlated with the morphologic and functional outcome of the filtering bleb. RESULTS: 1310-nm OCT was able to demonstrate the internal structure and the dimensions of filtering blebs, as well as the scleral flap and the deep sclerectomy location including Descemet membrane. Functioning filtering blebs showed a low OCT signal, small fluid-filled cysts, superficial microcystic layer, and a slack internal texture. High internal reflectivity indicated an earlier scarring of the filtering bleb. Nonfunctioning filtering blebs delivered a high OCT signal, no or few cysts, and a dense internal texture. These different OCT patterns correlated with the clinical outcome. CONCLUSIONS: Slit-lamp-adapted 1310-nm OCT allowed the noncontact observation and documentation of the postoperative healing course of filtering blebs after glaucoma surgery. Internal structures of the filtering bleb and deep sclerectomies could be visualized. Functioning and dysfunctioning filtering blebs delivered different OCT pattern and correlated with the clinical outcome. This could be a new way to assess the postoperative healing process with the possibility of earlier intervention in cases of impending scarring.

Dr. M. Muller, University Eye Hospital Schleswig-Holstein, Lübeck, Germany. mayamueller@gmx.de


Classification:

6.9.2 Optical coherence tomography (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)
12.8.1 Without tube implant (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
12.8.3 Non-perforating (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 8-4

Change Issue


advertisement

Oculus