advertisement
PURPOSE: To compare ocular surface temperature (OST) measures in patients with central retinal vein occlusion (CRVO) and controls. METHODS: Thirty-six patients with unilateral CRVO and 54 healthy volunteers were included in the study. OST was evaluated by infrared thermography. RESULTS: In CRVO eyes and in fellow, nonaffected eyes, OST values were lower than in controls (p < 0.05). Ischemic CRVO eyes showed lower temperatures than nonischemic ones. CONCLUSIONS: Infrared thermography may be helpful in the management of patients with CRVO.
Dr. A. Sodi, Eye Clinic, University of Firenze, Firenze, Italy
6.11 Bloodflow measurements (Part of: 6 Clinical examination methods)