advertisement

WGA Rescources

Abstract #22912 Published in IGR 11-1

Pericardium plug in the repair of the corneoscleral fistula after Ahmed Glaucoma Valve explantation

Yoo C; Kwon SW; Kim YY
Korean Journal of Ophthalmology 2008; 22: 268-271


We report four cases in which a pericardium (Tutoplast) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12-26 months). The pericardium (Tutoplast) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants.

Dr. C. Yoo, Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea


Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 11-1