Ratio of multifocal electroretinographic to retinal tomographic parameters in patients with suspected glaucoma

Kazarian EE
Vestnik Oftalmologii 2009; 125: 39-41


Based on the analysis of the data of a multifocal electroretinography FOK response and the retinal thickness in 38 patients with suspected glaucoma, the paper shows the inhibition of the external retinal biopotential and the lower retinal thickness in the posterior ocular pole. There is a correlation of these changes with light sensitivity alterations, as evidenced by quadrant analysis. It is stressed that monitoring of patients with suspected glaucoma must comprise a morphofunctional assessment using the current techniques. LA: Russian

E.E. Kazarian.


Classification:

6.7 Electro-ophthalmodiagnosis (Part of: 6 Clinical examination methods)
6.9.1.1 Confocal Scanning Laser Ophthalmoscopy (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.1 Laser scanning)