advertisement

Topcon

Abstract #26144 Published in IGR 12-2

Safety of DSAEK in Patients With Previous Glaucoma Filtering Surgery

Esquenazi S; Rand W
Journal of Glaucoma 2010; 19: 219-220


PURPOSE: To report 4 cases of Descemet stripping automated endothelial keratoplasty (DSAEK) in the presence of previous glaucoma filtering surgery. DESIGN: Observational case series. METHODS: Review of clinical data of 4 patients who underwent DSAEK successfully performed in the presence of previous glaucoma filtering surgery with endothelial survival rates comparable with larger series published previously and good postoperative intraocular pressure (IOP) control. RESULTS: The endothelial cell loss was 36% and 39% mean cell loss at 6 months and 1 year postoperatively. The IOP remained well controlled within target levels in all patients. No complications were reported in any of the 4 cases. CONCLUSIONS: Corneal endothelial failure can be successfully managed with DSAEK in glaucoma patients with previous filtering surgery with good endothelial survival rates and IOP control.

Department of Ophthalmology and Neuroscience Research, LSU Eye and Neuroscience Center, Louisiana State University, New Orleans, LA daggerOcular Surface Center, Rand Eye Institute, Deerfield Beach, FL.


Classification:

9.4.11.4 Glaucomas associated with corneal surgery (Part of: 9 Clinical forms of glaucomas > 9.4 Glaucomas associated with other ocular and systemic disorders > 9.4.11 Glaucomas following intraocular surgery)