Can mean central corneal thickness and its 24-hour fluctuation influence fluctuation of intraocular pressure?

Fogagnolo P; Capizzi F; Orzalesi N; Figus M; Ferreras A; Rossetti L
Journal of Glaucoma 2010; 19: 418-423


Purpose: To evaluate the influence of central corneal thickness (CCT) and its 24-hour fluctuation on 24-hour intraocular pressure (IOP) fluctuation in primary open-angle glaucoma. Methods: Forty consecutive patients underwent 24-hour evaluation (8 PM, midnight, 4 AM, 8 AM, noon, and 4 PM) of supine and sitting IOP, measured with handheld Perkins and Goldmann tonometer respectively, and of CCT measured using ultrasonic pachymeter. Thirty patients were treated with timolol 0.5% twice daily and latanoprost 0.005% once daily; 10 patients were untreated. Measurements were taken in both eyes, but only one eye per patient was used for analytical purposes. Three IOP curves were drawn: sitting position, supine position, and habitual body position (diurnal sitting measurements and nocturnal supine measurements). Fluctuation was calculated as the SD over the 24-hour curve. Differences in the 2 groups were inspected by means of t test; the correlations between IOP fluctuation and mean CCT, respectively, and its fluctuation were evaluated by means of regression analysis. Results: Untreated patients had higher IOP than the treated group (habitual body position: 22.1(plus or minus)5.1mm Hg vs. 16.0(plus or minus)3.0?mm Hg, P=0.004), but no differences were found for IOP fluctuations (habitual body position: 2.5(plus or minus)1.2?mm Hg vs. 2.3(plus or minus)0.8?mm Hg, P=0.32), mean CCT (542(plus or minus)38?(mu)m vs. 534(plus or minus)39?(mu)m, P=0.44), and CCT fluctuation (8.7(plus or minus)5.6?(mu)m vs. 6.5(plus or minus)3.0(mu)m, P=0.09). The correlation between IOP fluctuation and mean CCT and its fluctuation was not statistically significant at supine, sitting and habitual body positions (P?0.07; R(less-than or equal to)0.20). Conclusions: Twenty-four-hour IOP fluctuation was independent from CCT parameters in both treated and untreated glaucoma patients, regardless of body position at which IOP was measured.

P. Fogagnolo. Eye Clinic, San Paolo Hospital, Via di Rudini 8, 20142 Milano, Italy. fogagnolopaolo@googlemail.com


Classification:

6.1.2 Fluctuation, circadian rhythms (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)
6.1.3 Factors affecting IOP (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)



Issue 12-3

Change Issue


advertisement

Oculus