advertisement

Topcon

Abstract #45552 Published in IGR 13-2

Quantifying Discordance Between Structure and Function Measurements in the Clinical Assessment of Glaucoma

Zhu H; Crabb DP; Fredette MJ; Anderson DR; Garway-Heath DF
Archives of Ophthalmology 2011; 129: 1167-1174


OBJECTIVE: To evaluate a new method of quantifying and visualizing discordance between structural and functional measurements in glaucomatous eyes by predicting the visual field (VF) from retinal nerve fiber layer thickness (RNFLT) using a bayesian radial basis function. METHODS: Five GDx VCC RNFLT scans and 5 Humphrey 24-2 Swedish Interactive Thresholding Algorithm VF tests were performed for 50 glaucomatous eyes from 50 patients. A best-available estimate (BAE) of the true VF was calculated as the pointwise median of these 5 replications. This BAE VF was compared with every RNFLT-predicted VF from the bayesian radial basis function and every measured VF. Predictability of VFs from RNFLT was established from previous data. A structure-function pattern discordance map and a structure-function discordance index (scores of 0-1) were established from the predictability limits for each structure-function measurement pair to quantify and visualize the discordance between the structure-predicted and measured VFs. RESULTS: The mean absolute difference between the structure-predicted and BAE VFs was 3.9 dB. The mean absolute difference between measured and BAE VFs was 2.6 dB. The mean (SD) structure-function discordance index score was 0.34 (0.11). Ninety-seven (39%) of the structure-predicted VFs showed significant discordance (structure-function discordance index score >0.3) from measured VFs. CONCLUSIONS: On average, the bayesian radial basis function predicts the BAE VF from RNFLT slightly less well than a measured VF from the 5 VFs composing the BAE VF. The pattern discordance map highlights locations with structure-function discordance, with the structure-function discordance index providing a summary index. These tools may help clinicians trust the mutually confirmatory structure-function measurements with good concordance or identify unreliable ones with poor concordance.


Classification:

6.9.2.1 Anterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
6.6.2 Automated (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)



Issue 13-2

Change Issue


advertisement

Oculus