advertisement

WGA Rescources

Abstract #50269 Published in IGR 14-2

The effect of test variability on the structure-function relationship in early glaucoma

Gardiner SK; Johnson CA; Demirel S
Graefe's Archive for Clinical and Experimental Ophthalmology 2012; 250: 1851-1861


PURPOSE: To determine whether the weakness of the structure-function relationship could be produced by test variability alone, without implying underlying dissociation between the true rates of structural and functional change. METHODS: Perimetric mean deviation (MD), and rim area (RA) and cup volume (CV) from confocal scanning laser ophthalmoscopy, over six visits, were taken from 166 eyes of 92 participants with high-risk ocular hypertension or suspected/early glaucoma in the Portland Progression Project. Models were created of each measure's variability. A further model predicted the rate of functional change from the rate of structural change. These were used to generate realistic simulated sequences of both functional and structural data with different standard deviations σ between the underlying rates of change. 'Observed' structure-function relationships were calculated. An empirical p-value was derived, equaling the proportion of simulated series for which the 'observed' structure-function dissociation was greater than that seen in patient data. RESULTS: The correlation between the rates of structural (RA) and functional (MD) change was 0.171, consistent with σ < 0.02 dB/yr. Using CV, the correlation was -0.091, consistent with σ < 0.01 dB/yr. By comparison, the models predicted that the standard deviation of the rate of functional change for a healthy eye due to test variability would be 0.18 dB/yr. CONCLUSION: Test variability is sufficiently large that realistic patient data can be simulated without requiring a large variability between the underlying rates of structural and functional change. This absence of implied dissociation is a necessary condition for it to be valid to combine structural and functional measures to improve estimates of functional change and/or to reduce perimetric variability.

Discoveries In Sight Laboratories, Devers Eye Institute, Legacy Health System, 1225 NE 2nd Ave, Portland, OR, 97232, USA, sgardiner@deverseye.org.

Full article

Classification:

6.6.2 Automated (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)
6.9.1.1 Confocal Scanning Laser Ophthalmoscopy (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.1 Laser scanning)



Issue 14-2

Change Issue


advertisement

Oculus