Enhanced structure-function relationship in glaucoma with an anatomically and geometrically accurate neuroretinal rim measurement

Danthurebandara VM; Sharpe GP; Hutchison DM; Denniss J; Nicolela MT; McKendrick AM; Turpin A; Chauhan BC
Investigative Ophthalmology and Visual Science 2015; 56: 98-105


PURPOSE: To evaluate the structure-function relationship between disc margin-based rim area (DM-RA) obtained with confocal scanning laser tomography (CSLT), Bruch's membrane opening-based horizontal rim width (BMO-HRW), minimum rim width (BMO-MRW), peripapillary retinal nerve fiber layer thickness (RNFLT) obtained with spectral-domain optical coherence tomography (SD-OCT), and visual field sensitivity. METHODS: We examined 151 glaucoma patients with CSLT, SD-OCT, and standard automated perimetry on the same day. Optic nerve head (ONH) and RNFL with SD-OCT were acquired relative to a fixed coordinate system (acquired image frame [AIF]) and to the eye-specific fovea-BMO center (FoBMO) axis. Visual field locations were mapped to ONH and RNFL sectors with fixed Garway-Heath (VF(GH)) and patient-specific (VF(PS)) maps customized for various biometric parameters. RESULTS: Globally and sectorally, the structure-function relationships between DM-RA and VF(GH), BMO-HRW(AIF) and VF(GH), and BMO-HRW(FoBMO) and VF(PS) were equally weak. The R(2) for the relationship between DM-RA and VF(GH) ranged from 0.1% (inferonasal) to 11% (superotemporal) whereas that between BMO-HRW(AIF) and VF(GH) ranged from 0.1% (nasal) to 10% (superotemporal). Relatively stronger global and sectoral structure-function relationships with BMO-MRW(AIF) and with BMO-MRW(FoBMO) were obtained. The R(2) between BMO-MRW(AIF) and VF(GH) ranged from 5% (nasal) to 30% (superotemporal), whereas that between BMO-MRW(FoBMO) and VF(PS) ranged from 5% (nasal) to 25% (inferotemporal). The structure-function relationship with RNFLT was not significantly different from that with BMO-MRW, regardless of image acquisition method. CONCLUSIONS: The structure-function relationship was enhanced with BMO-MRW compared with the other neuroretinal rim measurements, due mainly to its geometrically accurate properties.

Department of Ophthalmology and Visual Sciences, Dalhousie University and Capital Health District Authority, Halifax, Nova Scotia, Canada.

Full article

Classification:

2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)
6.9.1.1 Confocal Scanning Laser Ophthalmoscopy (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.1 Laser scanning)
6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
6.6.2 Automated (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)