advertisement

Topcon

Abstract #60349 Published in IGR 16-4

Fibrin sealant-assisted revision of the exposed Ahmed tube

Choudhari NS; Neog A; Latka S; Srinivasan B
Middle East African Journal of Ophthalmology 2015; 22: 115-116


Tube exposure is a known complication of Ahmed glaucoma valve (AGV) implantation. Repair of the exposed tube is not easy. A 42-year-old monocular aphakic male had undergone retinal detachment repair with placement of an episcleral-encircling band followed by implantation of AGV. He presented to the clinic on routine review with exposure of the shunt tube. The complication was managed by placing scleral and conjunctival grafts over the exposed tube using a fibrin adhesive (Tisseel kit; Baxter AG, Vienna, Austria). The novel use of the fibrin sealant in the repair of AGV tube exposure was for better graft-integration.

Department of Glaucoma, Jadhavbhai Nathamal Singhvi, Sankara Nethralaya, Chennai, Tamil Nadu, India ; V S T Glaucoma Centre, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Hyderabad, India.

Full article

Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 16-4

Change Issue


advertisement

Oculus