advertisement

Topcon

Abstract #65788 Published in IGR 17-3

Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results

Neuhann TH
Journal of Cataract and Refractive Surgery 2015; 41: 2664-2671


PURPOSE: To evaluate long-term safety and efficacy of iStent trabecular micro-bypass stent implantation during cataract surgery in patients with primary open-angle, pseudo-exfoliation glaucoma, ocular hypertension, or secondary or post-traumatic glaucoma. SETTING: AaM Augenklinik am Marienplatz, Munich, Germany. DESIGN: Prospective, open-label, non-randomized study. METHODS: Preoperative and postoperative evaluations included intra-ocular pressure (IOP), topical ocular hypotensive medication use, cup/disc ratio, corrected-distance visual acuity (CDVA), complications, and adverse events. RESULTS: A single trabecular micro-bypass stent was implanted through the same temporal, limbal incision used for cataract surgery via phacoemulsification in a consecutive series of 62 eyes of 43 patients. To date, a total of 41 eyes have been followed for 3 years postoperatively, whereas long-term postoperative follow-up on the remaining patients is ongoing. Mean preoperative IOP was 24.1 ± 6.9 mm Hg on a mean of 1.8 medications (±0.9). Analyses of eyes with no secondary surgical intervention showed mean IOP reduction to 14.8 ± 4.2 mm Hg at 12 months (n = 61), 14.5 ± 2.2 mm Hg at 24 months (n = 42), and 14.9 ± 2.3 mm Hg at 36 months (n = 39). Medications were eliminated in 74% of eyes at 36 months. Five eyes, 4 with previous glaucoma surgeries and 1 with pseudo-exfoliation syndrome, required additional glaucoma surgery after stent implantation. No intra-operative or postoperative complications typically seen with conventional glaucoma surgeries occurred after stent implantation. At 36 months, CDVA was 20/40 or better in 38 eyes (93%). CONCLUSION: Trabecular micro-bypass stent implantation during cataract surgery was safe and effective in patients with ocular hypertension or glaucoma as measured by a sustained reduction in IOP and medication use and an excellent safety profile through 3 years after surgery. FINANCIAL DISCLOSURES: Dr. Neuhann has no financial or proprietary interest in any material or method mentioned. Glaukos Corp. provided editorial assistance in the preparation of the manuscript.

Full article

Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 17-3

Change Issue


advertisement

Oculus