advertisement

WGA Rescources

Abstract #66237 Published in IGR 17-3

Intraocular Pressure Reduction Is Associated with Reduced Venous Pulsation Pressure

Morgan WH; House PH; Hazelton ML; Betz-Stablein BD; Chauhan BC; Viswanathan A; Yu DY
PLoS ONE 2016; 11: e0147915

See also comment(s) by Ingeborg Stalmans & Luís Abegão Pinto


PURPOSE: To explore whether alterations in intraocular pressure (IOP) affect vein pulsation properties using ophthalmodynamometric measures of vein pulsation pressure. PATIENTS AND METHODS: Glaucoma patients had two retinal vein pulsation pressure (VPP) measurements from upper and lower hemiveins performed by ophthalmodynamometry at least 3 months apart. All subjects had VPP and IOP recorded at two visits, with standard automated perimetry, central corneal thickness (CCT) recorded at the initial visit. Where venous pulsation was spontaneous ophthalmodynamometry could not be performed and VPP was considered equal to IOP. Change in VPP was calculated and binarized with reduction in pressure scored 1 and no change or increase scored as 0. Data analysis used a mixed logistic regression model with change in VPP as response variable and change in IOP, visual field loss (mean deviation), CCT and time interval as explanatory variables. RESULTS: 31 subjects (20 females) with mean age 60 years (sd 11) were examined with change in VPP being significantly associated with change in IOP (odds ratio 1.6/mmHg, 95% CI 1.2 to 2.1 in the glaucoma patients but not suspect patients (p = 0.0005). CONCLUSION: Change in VPP is strongly associated with change in IOP such that a reduced intraocular pressure is associated with a subsequent reduction in VPP. This indicates that reduced IOP alters some retinal vein properties however the nature and time course of these changes is not known.

Lions Eye Institute, University of Western Australia, Nedlands, Australia.

Full article

Classification:

6.11 Bloodflow measurements (Part of: 6 Clinical examination methods)



Issue 17-3

Change Issue


advertisement

Topcon