Comparing Glaucomatous Disc Change Using Stereo Disc Viewing and the MatchedFlicker Software Program in Ophthalmologists-in-Training

Schaefer JL; Lukowski ZL; Meyer AM; Leoncavallo AJ; Greer A; Martorana GM; Zou B; Shuster JJ; Sherwood MB
American Journal of Ophthalmology 2016; 167: 88-95


PURPOSE: To compare the accuracy and speed of using the computerized MatchedFlicker software program (EyeIC Inc, Narberth, Pennsylvania, USA) to evaluate glaucomatous optic disc change against the traditional gold standard of manually examining stereoscopic disc photographs. DESIGN: A prospective evaluation of diagnostic technology. METHODS: Two resident ophthalmologists and 1 glaucoma fellow at the University of Florida independently evaluated 140 image pairs from 100 glaucomatous/ocular hypertensive patient eyes using a handheld stereo viewer and the MatchedFlicker program. Fifty had progression to glaucoma as determined by the Ocular Hypertension Treatment Study (OHTS) Optic Disc Reading Group and the OHTS Endpoint Committee in the OHTS, and 50 more had photographs taken a few minutes apart, which were negative controls with no progression. Twenty photograph pairs from each group were duplicated to determine reviewer variability. Photographs were examined in alternating blocks of 70 photograph pairs for each method, with the starting viewing method randomized. Reviewer accuracy and time to review for each method were measured. RESULTS: Using the handheld stereo viewer, the reviewers correctly identified progression or nonprogression in 76.0% of the slide pairs. Using the MatchedFlicker software, 87.6% were correctly identified (P = .011). Evaluator speed averaged 34.1 seconds per image pair with the stereo viewer vs 24.9 seconds with the MatchedFlicker program (P = .044). Overall, Flicker was significantly more specific but less sensitive than stereo slides. Trainees appeared more reluctant to identify glaucoma progression from slides than from Flicker. For the 2 less experienced trainees Flicker was significantly more accurate. CONCLUSION: The MatchedFlicker software had a greater accuracy and was quicker to perform than using a handheld stereoscopic viewer.

University of Florida, Department of Ophthalmology, Gainesville, Florida; Ross Eye Institute, University at Buffalo, Department of Ophthalmology, Buffalo, New York.

Full article

Classification:

15 Miscellaneous
2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)
6.8.2 Posterior segment (Part of: 6 Clinical examination methods > 6.8 Photography)



Issue 17-4

Change Issue


advertisement

Oculus