advertisement

WGA Rescources

Abstract #70915 Published in IGR 18-2

Gonioscopically Guided Nonpenetrating Cyclodialysis Cleft Repair: A Novel Surgical Technique

Rodrigues IA; Shah B; Goyal S; Lim KS
Journal of Current Glaucoma Practice 2017; 11: 31-34


AIM: We present a novel surgical technique for repair of persistent and symptomatic cyclodialysis clefts refractory to conservative or minimally invasive treatment. BACKGROUND: Numerous surgical techniques have been described to close cyclodialysis clefts. The current standard approach involves intraocular repair of cyclodialysis clefts underneath a full-thickness scleral flap. TECHNIQUE: Our technique employs intraoperative use of a direct gonioscope to guide a nonpenetrating surgical repair. Subsequently, a significantly less invasive, nonpenetrating technique utilizing a partial-thickness scleral flap can be performed that reduces potential risks associated with intraocular surgery. The direct gonioscope is also used for confirmation of adequate surgical closure of the cyclodialysis cleft prior to completion of surgery. This technique has been successfully carried out to repair traumatic chronic cyclodialysis clefts associated with hypotony in two patients. There were no significant adverse events as a result of using this technique. CONCLUSION: The novel technique described increases the likelihood of successful and permanent repair of cyclodialysis clefts with resolution of symptoms associated with hypotony, through direct intraoperative visualization of the cleft. CLINICAL SIGNIFICANCE: Gonioscopically guided nonpenetrating cyclodialysis cleft repair offers significant benefits over previously described techniques. Advantages of our technique include gonioscopic cleft visualization, enabling accurate localization of the area requiring repair, and subsequent confirmation of adequate closure of the cleft. Using a partial-thickness scleral flap is also less invasive and reduces risks associated with treatment of this potentially challenging complication of ocular trauma. HOW TO CITE THIS ARTICLE: Rodrigues IAS, Shah B, Goyal S, Lim S. Gonioscopically Guided Nonpenetrating Cyclodialysis Cleft Repair: A Novel Surgical Technique. J Curr Glaucoma Pract 2017;11(1):31-34.

Specialist Registrar, Department of Ophthalmology, St Thomas' Hospital, London United Kingdom.

Full article

Classification:

12.11 Cyclodialysis (Part of: 12 Surgical treatment)
6.4 Gonioscopy (Part of: 6 Clinical examination methods)



Issue 18-2

Change Issue


advertisement

WGA Rescources