advertisement

Topcon

Abstract #71258 Published in IGR 18-3

The relationship between central visual field sensitivity and macular ganglion cell/inner plexiform layer thickness in glaucoma

Lee JW; Morales E; Sharifipour F; Amini N; Yu F; Afifi AA; Coleman AL; Caprioli J; Nouri-Mahdavi K
British Journal of Ophthalmology 2017; 101: 1052-1058


AIMS: To explore the correlation of local macular ganglion cell/inner plexiform layer (GC/IPL) thickness measurements with sensitivity at individual test locations on the central 10-2 visual fields (VFs) in patients with glaucoma. METHODS: One hundred thirty-seven eyes of 125 patients with spectral domain optical coherence tomography (OCT) and 10-2 VFs were included. The exported thickness matrices (200×200) of GC/IPL measurements were centred on the fovea. Total deviation values at each test location were correlated with the 20 000 GC/IPL thickness measurements in the corresponding inferior or superior hemiretina, and areas of highest correlation were plotted. Macular structure-function relationships were also examined between six wedge-shaped GC/IPL sectors and the corresponding VF clusters. A multivariate model was built to identify the 10-2 VF test locations associated with each GC/IPL sector thickness. RESULTS: Average mean deviation on 10-2 VFs was -9.2±6.1 dB. The 10-2 VF test points demonstrated correlations with GC/IPL thickness in localised arcuate patterns mostly limited within the central 4.8×4.0 mm measurement ellipse (ρ=0.43-0.74, p<0.05 for all). Twenty-one test points of the 10-2 VF were the best predictors of sectoral GC/IPL thickness. Sectoral VF-OCT correlations were high (ρ=0.53-0.66, p<0.001) and did not significantly change after adjusting for retinal GC displacement (p>0.05). CONCLUSIONS: Macular OCT/VF relationships have localised arcuate characteristics in the central region of the macula. Given the overlapping nature of structure-function relationships, a smaller number of VF test locations may be used to summarise macular functional damage. TRIAL REGISTRATION NUMBER: NCT01742819.

Full article

Classification:

6.6.2 Automated (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)
6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
2.13 Retina and retinal nerve fibre layer (Part of: 2 Anatomical structures in glaucoma)



Issue 18-3

Change Issue


advertisement

Oculus