advertisement
Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was summarized using a time trend analysis of mean total deviation (mTD) and the association between mTD progression rate and a number of ocular parameters (including CST and ORA measurements) was assessed using mixed linear regression analysis. The optimal model of VF progression selected based on the corrected Akaike Information Criteria (AICc) included ORA's corneal hysteresis (CH) parameter as well as a number of CST measurements: mTD progression rate = 1.2-0.070 * mean GAT + 0.090 * CH-1.5 * highest concavity deformation amplitude with CST + 9.4 * A1 deformation amplitude with CST-0.05 * A2 length with CST (AICc = 125.8). Eyes with corneas that experience deep indentation at the maximum deformation, shallow indentation at the first applanation and wide indentation at the second applanation in the CST measurement are more likely to experience faster rates of VF progression.
Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan.
Full article6.1.1 Devices, techniques (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)
6.20 Progression (Part of: 6 Clinical examination methods)
2.2 Cornea (Part of: 2 Anatomical structures in glaucoma)