advertisement
PURPOSE: To demonstrate the utility of swept-source anterior segment optical coherence tomography (SS-AS-OCT) in guiding placement of transconjunctival sutures in hypotonous patients after a trabeculectomy. PATIENTS AND METHODS: This is a longitudinal case series of 10 eyes from 10 patients who required transconjunctival sutures after a trabeculectomy. SS-AS-OCT was used to aid in the placement of the sutures to improve the function of the overfiltering bleb. RESULTS: SS-AS-OCT reliably identified localized areas of overfiltering, allowing for targeted suture placement in 8 eyes. The 2 eyes in which localized areas of overfiltering were not found required further surgical intervention. CONCLUSIONS: SS-AS-OCT enhances transconjunctival suturing for overfiltering blebs when focal fluid accumulation is visualized.
*School of Engineering Science, Simon Fraser University, Burnaby †Faculty of Medicine ‡Faculty of Applied Science §Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, BC, Canada.
Full article12.8.11 Complications, endophthalmitis (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
6.9.2.1 Anterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
12.8.5 Other (Part of: 12 Surgical treatment > 12.8 Filtering surgery)