advertisement

Topcon

Abstract #75370 Published in IGR 19-2

Bruch's membrane opening minimum rim width : Correlation and diagnostic accuracy in comparison to peripapillary retinal nerve fiber layer thickness

Awe M; Khalili-Amiri S; Volkmann IR; Junker B; Framme C; Hufendiek K
Ophthalmologe 2017; 0:


BACKGROUND: Glaucoma is one of the main causes of blindness in the Western hemisphere. Because the disease often painlessly progresses it remains unnoticed until major optic nerve head damage occurs in many cases. That is why new, more sensitive diagnostic methods are needed. Bruch's membrane opening minimum rim width (BMO-MRW), measured with the new glaucoma module premium edition (GMPE) was recently introduced as a more accurate tool to detect glaucomatous changes. The purpose of this study was to assess the correlation of SPECTRALIS® spectral domain optical coherence tomography (SD-OCT) and the GMPE anatomic positioning module (APS module) for retinal nerve fiber layer thickness (RNFLT) measurements. The second aim was to assess the diagnostic accuracy of BMO-MRW. METHODS: Prospective study of 41 eyes (41 patients) with glaucoma and 26 eyes from 26 healthy controls. Scans were obtained using SPECTRALIS® SD-OCT and RNFLT was measured with both modules and compared using Spearman's rank test. The BMO-MRW was assessed by GMPE. Sensitivity, specificity and area under receiver operating characteristics curves (AUROC) of each sector of the optic nerve were calculated and compared using the method of Delong et al. RESULTS: We found a positive correlation (0.694-0.955, p < 0.0001) between RNFLT measurements by standard SD-OCT and all diameters of RNFLT of APS module within all sectors. The AUROC of RNFLT in standard SD-OCT was 0.693 for the inferior nasal sector (NI) and BMO-MRW was 0.85 in NI. The difference in AUROC was statistically significant (p = 0.0049). No other sector showed statistically significant differences. CONCLUSION: The RNFLT measurements of both modules showed a positive correlation and appear to be comparable. The BMO-MRW in one sector (NI) showed a significantly higher accuracy of measurement than standard RNFLT. All other sectors showed a comparable accuracy of measurement.

Universitätsklinik für Augenheilkunde, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625, Hannover, Deutschland. awe.marita@gmail.com.

Full article

Classification:

2.12 Choroid, peripapillary choroid, peripapillary atrophy (Part of: 2 Anatomical structures in glaucoma)
2.13 Retina and retinal nerve fibre layer (Part of: 2 Anatomical structures in glaucoma)



Issue 19-2

Change Issue


advertisement

Oculus