advertisement

Topcon

Abstract #79601 Published in IGR 20-2

Four-year results of a minimally invasive transscleral glaucoma gel stent implantation in a prospective multi-centre study

Lenzhofer M; Kersten-Gomez I; Sheybani A; Gulamhusein H; Strohmaier C; Hohensinn M; Burkhard Dick H; Hitzl W; Eisenkopf L; Sedarous F; Ahmed II; Reitsamer HA
Clinical and Experimental Ophthalmology 2019; 47: 581-587


IMPORTANCE: The transscleral XEN Glaucoma Gel Microstent (XEN-GGM, Allergan Plc., Parsippany, New Jersey) is implanted by a minimally invasive ab interno technique. BACKGROUND: The present study aims to assess the long-term clinical outcomes in patients after XEN-GGM implantation. DESIGN: This prospective, non-randomized, multi-centred study was conducted in three countries (Austria, Canada and Germany). PARTICIPANTS: Sixty-four consecutive eyes of 64 patients with open angle glaucoma received the XEN-GGM (63 μm) without Mitomycin C. Thirty-five (55%) were solo procedures, and 29 (45%) were combined with cataract surgery. METHODS: Visits were planned at baseline, 6 months, 1, 2, 3 and 4 years postoperatively. MAIN OUTCOME MEASURES: The main outcome measures were mean intraocular pressure (IOP), mean number of IOP lowering medication. Secondary outcome parameters were: visual acuity, visual fields and complete surgical failure (defined as presence of a secondary IOP lowering procedure or loss of light perception) at 4 years, postoperatively. RESULTS: Mean best-medicated baseline IOP was 22.5 ± 4.2 mmHg and decreased significantly to 13.4 ± 3.1 mmHg 4 years postoperatively (-40%, n = 34, P < 0.001). Mean number of IOP lowering medication decreased significantly from 2.4 ± 1.3 preoperatively to 1.2 ± 1.3 (-50%, n = 34, P < 0.001) postoperatively. Visual field mean deviation showed no significant change between preoperative and postoperative examinations. Complete surgical failure rate per year was 10%. CONCLUSIONS AND RELEVANCE: The XEN-GGM resulted in lower IOP and a reduction in medications from baseline over 4 years of follow-up. There was no detectable decrease in visual fields over the study. The surgical failure rate is comparable to other filtration surgeries.

Department of Ophthalmology and Optometry, University Clinic Salzburg, Paracelsus Medical University, Salzburg, Austria.

Full article

Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
12.8.3 Non-perforating (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 20-2

Change Issue


advertisement

Topcon