K-RIM (Corneal Rim) Angle Surgery Training Model

Arora A; Nazarali S; Sawatzky L; Gooi M; Schlenker M; Ahmed IK; Gooi P
Journal of Glaucoma 2019; 28: 146-149


PURPOSE: To develop an angle surgery training model for training an array of microincisional glaucoma surgery (MIGS) procedures. METHODS: We describe a method for preparing an angle surgery training model using human cadaveric corneoscleral rims. The model provides realistic tactile tissue simulation and excellent angle visualization requiring bimanual technique. Corneoscleral rims may be used multiple times and are prepared at low cost, allowing for a high volume of practice surgeries. RESULTS: This model allows for practice in bimanual surgical training using the gonioscopy lens for visualize alongside surgical tools. The in vivo surgical conditions and limited tactile feedback are recreated using human cadaveric eyes which nonhuman models fail to provide. Our model is prepared at low cost, with relative ease and also provides appropriate positioning of Schlemm canal and for high volume of practice as the canal can be used in 90-degree segments. CONCLUSIONS: Few angle surgery training models currently exist and none provide these necessary features. The model presented here aims to meet the growing demand for adequate training models required for technically advanced MIGS techniques.

Faculty of Medicine and Dentistry, University of Alberta Medical School, University of Alberta, Edmonton.

Full article

Classification:

12.8.3 Non-perforating (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
12.20 Other (Part of: 12 Surgical treatment)