advertisement

Topcon

Abstract #80962 Published in IGR 20-3

Comparison of the clinical estimation of cup-to-disk ratio by direct ophthalmoscopy and optical coherence tomography

Amedo AO; Koomson NY; Kobia Acquah E; Pascal TM; Atuahene J; Akowuah PK; Djeagbo PT; Baafi R
Therapeutic advances in ophthalmology 2019; 11: 2515841419827268


OBJECTIVE: To compare the clinical estimation of cup-to-disk ratio determined by direct ophthalmoscopy and optical coherence tomography in glaucoma diagnosis and monitoring. METHODS: A retrospective, cross-sectional study involving a review of 71 optical coherence tomography scans dating from June 2011 to January 2012 at a private imaging lab in Ghana. At the respective referring facilities, only 31 out of the 71 corresponding patient records were successfully reviewed. RESULTS: Majority (54.84%) of the 31 patient records successfully reviewed were women. The mean age was 44.54 ± 16.15 years. Cup-to-disk ratio was grouped into ⩽0.4, >0.4-0.6, >0.6-0.8, and >0.8-1.0 based on direct ophthalmoscopy values. The overall mean cup-to-disk ratio estimated by the optical coherence tomography and direct ophthalmoscopy were 0.72 ± 0.21 and 0.60 ± 0.26, respectively. Overall, there was no statistically significant difference in the mean cup-to-disk ratio estimation by direct ophthalmoscopy and optical coherence tomography [right eye ( = 0.0629); left eye ( = 0.0766)]. There was a statistically significant difference between direct ophthalmoscopy and optical coherence tomography cup-to-disk ratio estimation for values ⩽0.4 [right eye ( = 0.0061); left eye ( = 0.0063)] and values >0.4-0.6 [right eye ( = 0.0243); left eye ( = 0.0498)]. There was no statistically significant difference between conventional direct ophthalmoscopy and optical coherence tomography cup-to-disk ratio estimation for cup-to-disk ratio >0.6. CONCLUSION: We recommend clinicians document which method they use in evaluating optic nerve head parameters. This is to ensure that subsequent clinical decisions are not influenced by an apparent change in these parameters, especially cup-to-disk ratio as different methods might give different values.

Vision Research Group, Department of Optometry and Visual Science, College of Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana.

Full article

Classification:

6.5 Ophthalmoscopy (Part of: 6 Clinical examination methods)
2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)
6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)



Issue 20-3

Change Issue


advertisement

Topcon