advertisement

Topcon

Abstract #82335 Published in IGR 20-4

Aqueous Humor Dynamics in Uveitic Eyes

Alaghband P; Baneke AJ; Galvis E; Madekurozwa M; Chu B; Stanford M; Overby D; Lim KS
American Journal of Ophthalmology 2019; 208: 347-355


PURPOSE: To investigate aqueous humor dynamics in uveitic eyes. DESIGN: Cross-sectional study. PARTICIPANTS: Patients with recurrent (≥3 attacks) anterior uveitis (now quiescent) and being treated for glaucoma or ocular hypertension (OHT) (Group 1), previous recurrent anterior uveitis (≥3 attacks) without glaucoma or OHT (Group 2), and normal subjects with no ocular problems and IOP < 21 mm Hg at screening (control group; Group 3). METHODS: Patients had one-off measurements. Group 1 patients who were on antihypertensives were washed out for a 4-week period, prior to their study measurements. Main outcome measures were tonographic outflow facility, aqueous humor flow rate, and uveoscleral outflow. RESULTS: One hundred and one patients were screened between February 2014 and February 2017. Nine patients did not meet the inclusion criteria. Groups 1 and 3 each included 30 patients, and Group 2 included 32 patients. The mean intraocular pressure was higher in Group 1 compared to the others (25 ± 10.2 mm Hg in Group 1 vs 16 ± 2.7 mm Hg in Group 2 vs 16 ± 2.2 mm Hg in Group 3, P < .001). The tonographic outflow facility was lower in Group 1 compared to the others (0.18 ± 0.1 μL/min/mm Hg in Group 1 vs 0.25 ± 0.1 μL/min/mm Hg in Group 2 vs 0.27 ± 0.1 μL/min/mm Hg in Group 3, P = .005). However, aqueous humor flow rate was not statistically different (2.47 ± 0.9 μL/min in Group 1 vs 2.13 ± 0.9 μL/min in Group 2 vs 2.25 ± 0.7 μL/min in Group 3, P = .3). There was also no significant difference in calculated uveoscleral outflow. CONCLUSION: This is the first aqueous humor dynamics study in patients with uveitic glaucoma/OHT and recurrent anterior uveitis compared with age-matched controls. We have demonstrated that the elevated intraocular pressure seen in the uveitic glaucoma/OHT eyes (3-6 attacks) was due to reduced tonographic outflow facility. The aqueous humor flow rate was not detectibly different, nor did the calculated uveoscleral outflow demonstrate any discernible difference. However, the exact mechanism remains to be elucidated.

St Thomas Hospital, London, United Kingdom; King's College London, London, United Kingdom.

Full article

Classification:

9.4.6 Glaucomas associated with inflammation, uveitis (Part of: 9 Clinical forms of glaucomas > 9.4 Glaucomas associated with other ocular and systemic disorders)
2.6.2.1 Trabecular meshwork (Part of: 2 Anatomical structures in glaucoma > 2.6 Aqueous humor dynamics > 2.6.2 Outflow)
2.6.2.2 Uveoscleral (Part of: 2 Anatomical structures in glaucoma > 2.6 Aqueous humor dynamics > 2.6.2 Outflow)



Issue 20-4

Change Issue


advertisement

Oculus