Corneal Biomechanics and Visual Field Progression in Eyes with Seemingly Well-Controlled Intraocular Pressure

Susanna BN; Ogata NG; Jammal AA; Susanna CN; Berchuck SI; Berchuck SI; Medeiros FA
Ophthalmology 2019; 126: 1640-1646


PURPOSE: To investigate the incidence and risk factors for glaucomatous visual field progression in eyes with well-controlled intraocular pressure (IOP). DESIGN: Prospective cohort. PARTICIPANTS: A total of 460 eyes of 334 patients with glaucoma under treatment. METHODS: Study subjects had a mean follow-up of 4.3±0.8 years. Patients were classified as well controlled if all IOP measurements were less than 18 mmHg. Rates of visual field progression were calculated using ordinary least-squares linear regression of standard automated perimetry (SAP) mean deviation (MD) values over time. Progression was defined as a significantly negative MD slope (alpha = 0.05). MAIN OUTCOME MEASURES: Rates of SAP MD change; mean and peak IOP, and IOP fluctuation; and corneal biomechanics: corneal hysteresis (CH), central corneal thickness (CCT), and corneal index. RESULTS: Of the 179 eyes with well-controlled IOP, 42 (23.5%) demonstrated visual field progression. There was no significant difference between progressing and stable patients in baseline MD (-6.4±7.1 decibels [dB] vs. -6.0±6.2 dB; P = 0.346), mean IOP (11.7±2.0 mmHg vs. 12.1±2.3 mmHg; P = 0.405), IOP fluctuation (1.6±0.6 mmHg vs. 1.6±0.5 mmHg; P = 0.402), or peak IOP (14.3±1.9 mmHg vs. 14.6±2.1 mmHg; P = 0.926). Progressing eyes had significantly lower CH (8.6±1.3 mmHg vs. 9.4±1.6 mmHg; P = 0.014) and thinner CCT (515.1±33.1 μm vs. 531.1±42.4 μm; P = 0.018, respectively) compared with stable eyes. In the multivariate analysis, a 1 standard deviation lower corneal index, a summation of normalized versions of CH and CCT, resulted in a 68% higher risk of progression (odds ratio, 1.68; 95% confidence interval, 1.08-2.62; P = 0.021). CONCLUSIONS: Approximately one-quarter of eyes with well-controlled IOP may show visual field progression over time. Thin cornea and low CH are main risk factors.

Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina; ABC Foundation School of Medicine, Santo André, Brazil; Hamilton Glaucoma Center, University of California, San Diego, La Jolla, California.

Full article

Classification:

6.20 Progression (Part of: 6 Clinical examination methods)
2.2 Cornea (Part of: 2 Anatomical structures in glaucoma)



Issue 20-4

Change Issue


advertisement

Oculus