advertisement

Topcon

Abstract #82499 Published in IGR 20-4

Deep Learning and Glaucoma Specialists: The Relative Importance of Optic Disc Features to Predict Glaucoma Referral in Fundus Photographs

Phene S; Dunn RC; Hammel N; Liu Y; Krause J; Kitade N; Schaekermann M; Sayres R; Wu DJ; Bora A; Semturs C; Misra A; Huang AE; Spitze A; Medeiros FA; Maa AY; Gandhi M; Corrado GS; Peng L; Webster DR
Ophthalmology 2019; 126: 1627-1639


PURPOSE: To develop and validate a deep learning (DL) algorithm that predicts referable glaucomatous optic neuropathy (GON) and optic nerve head (ONH) features from color fundus images, to determine the relative importance of these features in referral decisions by glaucoma specialists (GSs) and the algorithm, and to compare the performance of the algorithm with eye care providers. DESIGN: Development and validation of an algorithm. PARTICIPANTS: Fundus images from screening programs, studies, and a glaucoma clinic. METHODS: A DL algorithm was trained using a retrospective dataset of 86 618 images, assessed for glaucomatous ONH features and referable GON (defined as ONH appearance worrisome enough to justify referral for comprehensive examination) by 43 graders. The algorithm was validated using 3 datasets: dataset A (1205 images, 1 image/patient; 18.1% referable), images adjudicated by panels of GSs; dataset B (9642 images, 1 image/patient; 9.2% referable), images from a diabetic teleretinal screening program; and dataset C (346 images, 1 image/patient; 81.7% referable), images from a glaucoma clinic. MAIN OUTCOME MEASURES: The algorithm was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity for referable GON and glaucomatous ONH features. RESULTS: The algorithm's AUC for referable GON was 0.945 (95% confidence interval [CI], 0.929-0.960) in dataset A, 0.855 (95% CI, 0.841-0.870) in dataset B, and 0.881 (95% CI, 0.838-0.918) in dataset C. Algorithm AUCs ranged between 0.661 and 0.973 for glaucomatous ONH features. The algorithm showed significantly higher sensitivity than 7 of 10 graders not involved in determining the reference standard, including 2 of 3 GSs, and showed higher specificity than 3 graders (including 1 GS), while remaining comparable to others. For both GSs and the algorithm, the most crucial features related to referable GON were: presence of vertical cup-to-disc ratio of 0.7 or more, neuroretinal rim notching, retinal nerve fiber layer defect, and bared circumlinear vessels. CONCLUSIONS: A DL algorithm trained on fundus images alone can detect referable GON with higher sensitivity than and comparable specificity to eye care providers. The algorithm maintained good performance on an independent dataset with diagnoses based on a full glaucoma workup.

Google Health, Google LLC, Mountain View, California.

Full article

Classification:

6.30 Other (Part of: 6 Clinical examination methods)
6.9.5 Other (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)
2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)



Issue 20-4

Change Issue


advertisement

Oculus