advertisement

Topcon

Abstract #84692 Published in IGR 21-1

Electrophysiology in Glaucoma

Senger C; Moreto R; Watanabe SES; Matos AG; Paula JS
Journal of Glaucoma 2020; 29: 147-153


OBJECTIVES: Electrophysiological testing of the visual system has been continuously used in studies involving the evaluation of retinal ganglion cells and the diagnosis of glaucoma. This study aims to review the results of recent studies regarding the clinical applicability of electrophysiological tests to glaucoma. METHODS: A systematic review of the literature was carried out by 2 independent reviewers using the PubMed and EMBASE electronic databases, searching for articles published in English from January 1, 2014 to July 1, 2019 using a combination of the following keywords: ("glaucoma" OR "ocular hypertension") AND ("electrophysiolog" OR "electroretinogra" OR "ERG" OR "mfERG" OR "Pattern-reversal electroretinography" OR "PERG" OR "mfPERG" OR "photopic negative response" OR "pattern electroretinogram" OR "visual evoked potential" OR "multifocal electroretinography" OR "multifocal electroretinogram" OR "electro-oculography" OR "multifocal VEP" OR "mf-ERG"). A total of 38 studies were selected and the data of 30 of them were tabulated in this review. RESULTS: Among the 30 studies selected, the photopic negative response and the reversal pattern electroretinogram were found to be the major methods used to record the electroretinographic responses generated by the retinal ganglion cell. Their multifocal versions and the multifocal visual evoked potential were also proposed during this period. In general, the results underscored a consistent but general correlation between the amplitude and latency measures and routine tests for glaucoma, such as perimetry and optical coherence tomography. DISCUSSION: In agreement with previous reviews, clinical electrophysiological testing of the visual system reasonably matched with both the structural and functional analyses for glaucoma. No definitive indications of these tests have been established either at early detection or during follow-up of the disease, and easier protocols and better topographical correspondence with current glaucoma tests are warranted for their routine use.

Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto.

Full article

Classification:

6.7 Electro-ophthalmodiagnosis (Part of: 6 Clinical examination methods)



Issue 21-1

Change Issue


advertisement

Oculus