A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag

Takada Y; Sumioka T; Ishikawa N; Yasuda S; Komori R; Saika S
Case Reports in Ophthalmology 2020; 11: 60-67


We observed repeated episodes of rapid increases in intraocular pressure (IOP) considered to be caused by an in-the-bag intraocular lens (IOL) instability in a patient with an implanted IOL. As acute glaucoma attack-like increase in IOP was noted in the left eye on November 8, she was admitted to Wakayama Medical University Hospital. The findings at the first examination included an IOP of 62 mm Hg, instability of a PMMA one-piece IOL, shallow anterior chamber, narrow angle, moderate mydriasis, and loss of pupillary light reaction in the left avitreous eye. On November 15, a 6-mm Hg increase in IOP was observed during 60-min dark room prone provocative testing. After the first examination, the patient perceived pain and reduced visual acuity of the left eye and emergently consulted our hospital twice. Despite miosis, normalization of the anterior chamber depth and IOP with widening of the angle were achieved by resting in the supine position. These episodes were thought to be caused by instability and anterior shift of the IOL. On January 17, 2018, suture fixation of the in-the-bag IOL was performed. The IOL was fixed by transscleral suturing of the bilateral supporting parts to the sclera. Recurrence of sudden ophthalmalgia, instability of the in-the-bag IOL, and an increase in IOP have not been observed for 1 year after surgical treatment. Instability of an in-the-bag IOL caused repeated acute angle-closure glaucoma-like attacks. The situation was well treated by suturing and fixing the haptics of IOL to the sclera.

Department of Ophthalmology, Wakayama Medical University, Wakayama, Japan.

Full article

Classification:

9.4.11.2 Glaucomas in aphakia and pseudophakia (Part of: 9 Clinical forms of glaucomas > 9.4 Glaucomas associated with other ocular and systemic disorders > 9.4.11 Glaucomas following intraocular surgery)
6.1.3 Factors affecting IOP (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)



Issue 21-1

Change Issue


advertisement

Oculus