advertisement

Topcon

Abstract #90591 Published in IGR 21-3

Optical Coherence Tomography Can Be Used to Assess Glaucomatous Optic Nerve Damage in Most Eyes With High Myopia

Zemborain ZZ; Jarukasetphon R; Tsamis E; Tsamis E; Tsamis E; De Moraes CG; Ritch R; Hood DC
Journal of Glaucoma 2020; 29: 833-845


PRECIS: It is generally assumed that optical coherence tomography (OCT) cannot be used to diagnose glaucomatous optic neuropathy (GON) in high myopes. However, this study presents evidence that there is sufficient information in OCT scans to allow for accurate diagnosis of GON in most eyes with high myopia. PURPOSE: The purpose of this study was to test the hypothesis that glaucomatous damage can be accurately diagnosed in most high myopes via an assessment of the OCT results. PATIENTS AND METHODS: One hundred eyes from 60 glaucoma patients or suspects, referred for OCT scans and evaluation, had corrected spherical refractive errors worse than -6 D and/or axial lengths ≥26.5 mm. An OCT specialist judged whether the eye had GON, based upon OCT circle scans of the disc and cube scans centered on the macula. A glaucoma specialist made the same judgement using all available information (eg, family history, repeat visits, intraocular pressure, 10-2 and 24-2 visual fields, OCT). A reference standard was created based upon the glaucoma specialist's classifications. In addition, the glaucoma specialist judged whether the eyes had peripapillary atrophy (PPA), epiretinal membrane (ERM), tilted disc (TD), and/or a paravascular inner retinal defect (PIRD). RESULTS: The OCT specialist correctly identified 97 of the 100 eyes using the OCT information. In 63% of the cases, the inner circle scan alone was sufficient. For the rest, additional scans were requested. In addition, 81% of the total eyes had: PPA (79%), ERM (18%), PIRD (26%), and/or TD (48%). CONCLUSIONS: For most eyes with high myopia, there is sufficient information in OCT scans to allow for accurate diagnosis of GON. However, the optimal use of the OCT will depend upon training to read OCT scans, which includes taking into consideration myopia related OCT artifacts and segmentation errors, as well as PPA, ERM, PIRD, and TD.

*Department of Psychology, Columbia University †Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai ‡Bernard and Shirlee Brown Glaucoma Research Laboratory §Department of Ophthalmology, Columbia University Medical Center, Edward S. Harkness Eye Institute, New York, NY.

Full article

Classification:

8.1 Myopia (Part of: 8 Refractive errors in relation to glaucoma)
6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)



Issue 21-3

Change Issue


advertisement

Oculus