BACKGROUND: Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision. The variable clinical manifestations may result in differential diagnostic difficulties. The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement. Therefore, we analyzed the agreement, difference, and correlation of chamber angle parameters such as angel opening distance at 500 μm (AOD500) and trabeculo-iris space area at 500 μm (TISA500) measured by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). AIM: To compare the differences, correlation, and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM. METHODS: Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects (72 eyes). All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University. Data of the two groups (AOD500 and TISA500) were compared by nonparametric tests. Pearson correlative analysis and Bland-Altman analysis were used to compare the correlation and agreement. RESULTS: There were no significant differences between AS-OCT and UBM in measuring AOD500 (1 = 0.110, 2 = 0.633, 3 = 0.078, and 4 = 0.474) and TISA500 (1 = 0.584, 2 = 0.889, 3 = 0.297, and 4 = 0.550) of the four quadrants of the anterior chamber angle. There was a high correlation in measuring AOD500 (1 = 0.562, 2 = 0.671, 3 = 0.635, and 4 = 0.720; < 0.001) and TISA500 (1 = 0.584, 2 = 0.889, 3 = 0.297, and 4 = 0.550; < 0.001). There was a good agreement in measuring AOD500 and TISA500 by the two modalities. CONCLUSION: There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM. They are interchangeable under some circumstances. AS-OCT proves to be a better early screening tool for glaucoma.
Department of Ophthalmology, Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Key Laboratory of Lens Research of Liaoning Province, Shenyang 110005, Liaoning Province, China.
Full article6.12 Ultrasonography and ultrasound biomicroscopy (Part of: 6 Clinical examination methods)
2.4 Anterior chamber angle (Part of: 2 Anatomical structures in glaucoma)
6.9.2.1 Anterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)