Local Macular Thickness Relationships between 2 OCT Devices

Mahmoudinezhad G; Mohammadzadeh V; Amini N; Toriz V; Pourhomayoun M; Heydarzadeh S; Mylavarapu A; Morales E; Caprioli J; Nouri-Mahdavi K
Ophthalmology. Glaucoma 2021; 4: 209-215


PURPOSE: To compare local ganglion cell-inner plexiform layer (GCIPL) thickness measurements between 2 OCT devices and to explore factors that may influence the difference in measurements. DESIGN: Cross-sectional study. PARTICIPANTS: Sixty-nine glaucoma eyes (63 patients) with evidence of central damage or mean deviation (MD) of -6.0 dB or worse on a 24-2 visual field (VF). METHODS: Cirrus and Spectralis OCT macular volume scans were exported, data from the central 20° of both OCT devices were centered and aligned, and 50 × 50 arrays of 0.4° × 0.4° superpixels were created. We estimated nonparametric (Spearman's) correlations and used Bland-Altman plots to compare GCIPL thickness measurements between the two OCTs at the superpixel level. Factors that may have influenced the differences between thickness measurements between the two devices were explored with linear mixed models. MAIN OUTCOME MEASURES: Pooled and individual-eye Spearman's correlation and agreement between thickness measurements from the two devices. RESULTS: The median 24-2 VF MD was -6.8 dB (interquartile range [IQR], -4.9 to -12.3 dB). The overall pooled Spearman's correlation between the two devices for all superpixels and eyes was 0.97 (P < 0.001). The median within-eye correlation coefficient was 0.72 (IQR, 0.59-0.79). Bland-Altman plots demonstrated a systematic bias in most individual eyes, with Spectralis GCIPL measurements becoming larger than Cirrus measurements with increasing superpixel thickness. The average superpixel thickness and distance to the fovea influenced the thickness difference between the two devices in multivariate models (P < 0.001). CONCLUSIONS: Local macular thickness measurements from the Spectralis and Cirrus devices are highly correlated, but not interchangeable. Differences in thickness measurements between the two devices are influenced by the location of superpixels and their thickness.

Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California.

Full article

Classification:

6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
2.13 Retina and retinal nerve fibre layer (Part of: 2 Anatomical structures in glaucoma)



Issue 21-3

Change Issue


advertisement

Oculus