PURPOSE: To investigate 24-hour nyctohemeral intraocular pressure (IOP)-related patterns with contact lens sensors (CLSs) in eyes with primary open-angle glaucoma (POAG) with normal baseline IOP (i.e., normal-tension glaucoma [NTG]) and healthy controls. DESIGN: Prospective, case-control study. PARTICIPANTS: Thirty eyes of 30 patients with NTG, who had had a wash-out period for their IOP-lowering treatment, and 20 eyes of 20 healthy volunteer subjects. METHODS: Patients and subjects were hospitalized for the purposes of 24-hour CLS (SENSIMED Triggerfish; Sensimed AG, Lausanne, Switzerland) measurement. The IOP-related patterns during wake and sleep times over the course of the 24 hours were compared between the 2 groups. The 24-hour ambulatory blood pressure and posture were monitored simultaneously. A generalized linear model was used to find the factors associated with NTG. MAIN OUTCOME MEASURES: The IOP-related patterns, including mean and standard deviation (SD) of measurements, amplitude of cosine-fit curve, acrophase (signal peak), and bathyphase (signal trough) values (millivolt equivalents [mVEq]). RESULTS: The SDs of the 24-hour CLS measurements were significantly greater in NTG eyes than in healthy controls (112.51±26.90 vs. 85.18±29.61 mVEq, P = 0.002). The amplitudes of cosine-fit curve (141.88±39.96 vs. 106.08±41.49 mVEq, P = 0.004) and acrophase values (277.74±129.80 vs. 190.58±127.88 mVEq, P = 0.024), mostly measured during nocturnal period, were significantly greater in NTG eyes than in healthy controls. The NTG subjects slept longer in the lateral decubitus posture than the healthy controls (199.1±137.8 vs. 113.2±86.2 minutes, P = 0.009). In the multivariable generalized linear model, the greater amplitude of cosine-fit curve (β = 0.218, P = 0.012) and greater time of decubitus posture during sleep (β = 0.180, P = 0.004) were found to be significantly associated with NTG. CONCLUSIONS: Continuous monitoring of 24-hour IOP-related values with CLS can be useful for assessment of glaucoma risk, especially for patients with NTG whose IOP appears to be in the normal range. Fluctuation of 24-hour IOP-related values and posture during sleep time might be associated with NTG.
Department of Ophthalmology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Full article6.1.2 Fluctuation, circadian rhythms (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)
6.1.1 Devices, techniques (Part of: 6 Clinical examination methods > 6.1 Intraocular pressure measurement; factors affecting IOP)
9.2.4 Normal pressure glaucoma (Part of: 9 Clinical forms of glaucomas > 9.2 Primary open angle glaucomas)
8.3 Contact lenses (Part of: 8 Refractive errors in relation to glaucoma)