advertisement

Topcon

Abstract #92309 Published in IGR 22-1

Acute Glaucoma Filtering Surgery Failure following Herpes Zoster Ophthalmicus Infection

Kandarakis SA; Diagourtas A; Petrou P; Vingopoulos F; Droutsas K; Papakonstantinou E; Georgalas I
Case Reports in Ophthalmology 2021; 12: 324-329


Herein, we report a case of acute failure of a previously successful trabeculectomy, following an infection with herpes zoster ophthalmicus (HZO). HZO remains a common infection, especially among elderly and immunocompromised patients. There is a strong link between HZO infection, the incidence of secondary glaucoma, and the need for glaucoma filtering surgery. Though, to our knowledge, there are no cases reporting on the effect that a concomitant infection may have on a previously successful trabeculectomy. In our case, a 76-year-old immunocompetent male with primary open-angle glaucoma in both eyes and a history of a successful right eye trabeculectomy 1 year earlier presented with acute primary HZO involving the ophthalmic branch of the right trigeminal nerve. Appropriate topical and systemic treatment was immediately initiated. Three days later, the trabeculectomy bleb showed hyperemia and flattening and concomitant rise of intraocular pressure was noted. A week later, the cutaneous signs were improving yet the trabeculectomy had failed and high intraocular pressure was established, requiring both topical and systemic antiglaucoma medications. Our study suggests that a previously successful trabeculectomy may manifest signs of compromise and subsequent failure following a HZO infection.

1st Opthhalmology Department, "G.Gennimatas" Hospital, National and Kapodistrian University of Athens, Athens, Greece.

Full article

Classification:

12.8.11 Complications, endophthalmitis (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
9.4.6 Glaucomas associated with inflammation, uveitis (Part of: 9 Clinical forms of glaucomas > 9.4 Glaucomas associated with other ocular and systemic disorders)



Issue 22-1

Change Issue


advertisement

Topcon