advertisement

Topcon

Abstract #12165 Published in IGR 7-2

Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography 3000

Choi MG; Han M; Kim YI; Lee JH
Korean Journal of Ophthalmology 2005; 19: 40-46


This study was performed to evaluate optic disc appearance, retinal nerve fiber layer (RNFL) thickness, and macular thickness in normal, ocular hypertensive (OHT) and glaucomatous eyes using optical coherence tomography (OCT) 3000. One hundred fifty-eight eyes of 167 consecutive subjects were enrolled: 60 normal, 53 OHT, and 54 glaucomatous. OCT topographic parameters of cup diameter, cup area, rim area, and cup/disc area ratio were significantly less in OHT eyes than in normal eyes and were significantly less in glaucomatous eyes than in normal and OHT eyes. RNFL was significantly thinner in OHT eyes than in normal eyes in the inferior quadrant, and in glaucomatous eyes than in OHT and normal eyes in the mean and for all four quadrants. Macular thickness was significantly thinner in glaucomatous eyes than in OHT and normal eyes throughout all subdivisions. Optic disc parameters, and RNFL and macular thickness measurements made with OCT may be useful in the clinical assessment of glaucoma.

Dr. M.G. Choi, Department of Ophthalmology, Inje University Busan Paik Hospital, Busan, Korea


Classification:

6.9.2 Optical coherence tomography (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)



Issue 7-2

Change Issue


advertisement

Oculus