advertisement

Topcon

Abstract #12307 Published in IGR 7-2

Choroidal perfusion measurements made with optical coherence tomography

Wu FI; Glucksberg MR
Applied Optics 2005; 44: 1426-1433


Choroidal perfusion measurements are complicated by the choroid's location posterior to the retina and its associated retinal blood vessels. Optical coherence tomography is a relatively new imaging technique with sufficient spatial resolution to isolate choroidal backscattering events from the posterior eye. We modified a speckle imaging algorithm to analyze sequential axial depth scans obtained from posterior rat eye to obtain an indicator of choroidal perfusion. This indicator is correlated with known changes in choroidal blood flow in response to increased intraocular pressure.

Dr. F.I. Wu, Department of Biomedical Engineering, Northwestern University, Tech Building E310, 2145 Sheridan Road, Evanston, Illinois 60201, USA


Classification:

6.9.2 Optical coherence tomography (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)
6.11 Bloodflow measurements (Part of: 6 Clinical examination methods)



Issue 7-2