Clinical examination methods: Visual acuity

Erik Greve

Comment by Erik Greve on:

12397 Random measurement error in visual acuity measurement in clinical settings, Leinonen J; Laakkonen E; Laatikainen L, Acta Ophthalmologica Scandinavica, 2005; 83: 328-332


Find related abstracts


Our visual acuity measurements may not be that stable. Although visual acuity is usually a late concern to glaucomatologists it may be good to learn from Leinonen et al. (546) that the random measurement error of visual acuity measurements may be in a range from 0.3 to 1.3 for the Snellen chart (SDME log MAR 0.04 in eyes with good vision, log MAR 0.09 xx bad vision). Changes of visual acuity should be judged (as ever) in the light of inherent variability.