The correlation coefficient between mean RNFL thickness around
the optic disc and mean deviation of the HFA in OAG eyes was greater
when using the Fourier domain OCT (FD-OCT) than the Time domain OCT
(TD-OCT). RNFL thickness measured with the FD-OCT was more
sensitively correlated with VFD in OAG eyes. (R. Sakata et al.,
Tokyo)
Late complications of trabeculectomy MMC0.4% or MMC0.2% did not
differ significantly. However, the MMC0.4% group carried higher
complete success rates. (S. Srisamran et al., Bangkok)
In 35 glaucoma eyes that had undergone Ahmed glaucoma valve (AGV)
implantation, there was a statistically significant corneal
endothelial cell loss in the operated eye after implant surgery,
compared to the other eye. The cell loss increased over time, up to
18.6% at two years after surgery. (C. Kim et al., Daejon)
Dynamic contour tonometry( DCT) measurements in normal subjects
seem to provide an estimate of IOP that is less influenced by
central corneal thickness than those provided by Goldmann
applanation tonometry. (S. Jamorsuwan)
IOP reducing efficacy of Bimatoprost 0.03% in chronic angle
closure glaucoma with 360 degree synechial closure is comparable to
patients with primary open angle glaucoma and ocular hypertension.
(N. Choithram)
A population-based study, the Tajimi Study, revealed that the
mean intraocular pressure by Goldmann applanation tonometry (GAP)
was 14.5mmHg in adult non-glaucoma Japanese aged 40 yrs or older.
(A. Iwase)
Anterior segment optical coherence tomography (Visante OCT) is a
commercially available imaging device enabling non-invasive and
non-contact analysis of the anterior chamber(AC). It provided images
of the scleral spur, angle recess and canal of Schlemm. In narrow
angle group(57 eyes) and open angle group(60 eyes), Visante OCT was
able to non-invasively visualize the AC angle in all eyes of the
open angle group and in 94.7% of the narrow angle group. (N. Mataki)
Four consecutive patients with neovascular glaucoma (NVG) due to
proliferative diabetic retinopathy (PDR), intravitreal avastin○,R
leads to a rapid regression of iris and angle neovascularization
even in patients who had undergone PRP along with vitrectomy. (Y.
Kita)
In 30 eyes of 30 open angle glaucoma (OAG) patients,
three-dimensional mapping
of RNFL thickness determined with the Fourier-domain OCT is useful
to detect RNFL defects in OAG eyes especially in myopic eyes. (S.
Konno)
Needle revision (NR) followed by subconjunctival injection of
0.1ml of 0.02 rather than 0.1mg/ml MMC is an effective method for
the treatment of the failed filtering blebs after trabeculectomy.
(S. Hyung)