The assessment of the filtering bleb function with anterior segment optical coherence tomography

Tominaga A; Miki A; Yamazaki Y; Matsushita K; Otori Y
Journal of Glaucoma 2010; 19: 551-555


Purpose: To assess the usefulness of anterior segment optical coherence tomography (AS-OCT) in evaluating postoperative filtering bleb function. Methods: Forty-eight eyes of 39 patients who had earlier undergone trabeculectomy were enrolled. Blebs were imaged with a commercially available AS-OCT system. The correlation between intraocular pressure (IOP) and 4 quantitative parameters, bleb height, bleb wall thickness, and the height and extent of internal cavity, and 2 qualitative parameters, bleb wall reflectivity, and the presence or absence of posterior episcleral fluid, were analyzed. Results: Of the 39 participants, 25 (64.1%) were males (mean age, 65.3(plus or minus)10.0 y). The height and extent of the internal cavity and the bleb height were not correlated with the IOP. The bleb wall thickness was negatively (P=0.004) correlated with the IOP. The mean IOP in eyes with a low-reflectivity bleb wall was significantly (P=0.001) lower than in eyes with a high-reflectivity wall. The IOP levels were significantly (P=0.008) lower in eyes with posterior episcleral fluid than in eyes without it. Conclusions: AS-OCT is a useful tool to evaluate filtering bleb function. The height and extent of the total bleb and the internal cavity were not correlated with IOP control. A low-reflectivity wall and the presence of episcleral fluid were associated with lower IOP. Copyright (copyright) 2010 by Lippincott Williams & Wilkins.

A. Miki. Department of Ophthalmology, Osaka University Medical School, 2-2 Yamadaoka, Suita, 565-0871, Japan. amiki@ophthal.med.osaka-u.ac.jp


Classification:

6.9.2.1 Anterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
12.8.1 Without tube implant (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 12-4

Change Issue


advertisement

Oculus