Early vs late intraocular pressure following trabeculectomy with releasable suture in advanced glaucoma

Sukhija J; Jain AK
Annals of ophthalmology (Skokie, Ill.) 2006; 38: 127-130


We retrospectively studied long-term outcome after trabeculectomy with releasable suture in advanced glaucoma in 67 consecutive glaucomic eyes. Intraocular pressure (IOP) was recorded preoperatively and periodically following surgery for up to 2 years. Early ( < 1 month) postoperative IOP was a reasonable indicator of long-term IOP control in eyes with advanced glaucoma.

Dr. A.K. Jain, Department of Ophthalmology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India