advertisement

Topcon

Abstract #21225 Published in IGR 10-2

The use of anterior segment optical coherence tomography in glaucoma drainage implant surgery

Au L; Fenerty C
Ophthalmic Surgery Lasers and Imaging 2008; 39: 164-166


Anterior segment optical coherence tomography is a rapid, non-contact method of assessing anterior segment structures and has high reliability and repeatability. Three cases are presented to illustrate how this technology can be used in the assessment and management of a glaucoma drainage implant. Anterior segment optical coherence tomography provides high-resolution images of the glaucoma drainage implant to assess its position, patency, drainage, and the intraluminal stenting suture. This proved to be useful in the case of postoperative hypotony. The non-contact advantage is useful in pediatric patients.

Dr. L. Au, Manchester Royal Eye Hospital, Manchester, UK


Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)
6.9.2.1 Anterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)



Issue 10-2

Change Issue


advertisement

Oculus