Heidelberg Retina Tomograph (HRT3) in population-based epidemiology: Normative values and criteria for glaucomatous optic neuropathy

Ramdas WD; Wolfs RCW; Hofman A; de Jong PTVM; Vingerling JR; Jansonius NM
Ophthalmic Epidemiology 2011; 18: 198-210


Purpose: To establish normative values for Heidelberg Retina Tomograph (HRT3) variables and to develop HRT3-based criteria for glaucomatous optic neuropathy for epidemiological research in a white population. Methods: Consecutive participants in the Rotterdam Study were examined with HRT and simultaneous stereoscopic fundus photography (ImageNet) in addition to other ophthalmic examinations including intraocular pressure (IOP) measurements and perimetry. Normative values for all HRT3 variables were determined in participants who met all the following criteria: no glaucomatous visual field loss (GVFL), an IOP of 21mmHg or less, no IOP lowering treatment, and a negative family history of glaucoma. Sensitivity was determined in participants with glaucomatous visual field loss at a fixed high specificity of 97.5% - a value commonly used in population-based epidemiology. Results: A total of 2516 participants were included in this study of whom 66 had glaucomatous visual field loss in at least one eye and 1680 fulfilled the criteria for contributing to the normative values. The HRT3 linear cup-disc ratio (LCDR) variable, adjusted for disc area, showed the highest sensitivity, 35%, at the required specificity of 97.5%. The 97.5th percentile of the LCDR was 0.67 for small discs (up to 1.5mm(2)), 0.73 for medium-sized discs and 0.79 for large discs (above 2.0mm(2)). The HRT3 Glaucoma Probability Score and previously published linear discriminant functions showed a lower sensitivity than LCDR at this specificity. Conclusions: At the high specificity of 97.5% as is commonly used in population-based epidemiology, the sensitivity of the HRT3 is low - albeit not lower than that of the vertical cup-disc ratio as assessed with simultaneous stereoscopic fundus photography and analyzed with the ImageNet software. The LCDR variable, stratified for disc area, seems to be the most suitable variable to develop criteria for glaucomatous optic neuropathy for epidemiological purposes. (copyright) 2011 Informa Healthcare USA, Inc.

J.R. Vingerling. Department of Ophthalmology, Epidemiology and Biostatistics, Erasmus Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, Netherlands. Email: j.vingerling@erasmusmc.nl


Classification:

6.9.1.1 Confocal Scanning Laser Ophthalmoscopy (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.1 Laser scanning)



Issue 13-4

Change Issue


advertisement

Oculus